| Sign In | Join Free | My ecer.com.ru |
|
Brand Name : SAFEGAS
Model Number : MiniMeta
Certification : IECEX/ATEX/EMC/CE
Place of Origin : China
MOQ : 1
Price : Negotiable
Payment Terms : ,T/T
Supply Ability : 100 pieces/day
Delivery Time : 3 work days
Packaging Details : Carton
Gas Detected : Specified according to application.
Measure range : Specified according to application.
Resolution : Specified according to application.
Principle : Electrochemical principle
Accuracy : ≤±2-5%FS (depending on the specific sensor)
Response time(T90) : 15-30s(depending on the specific sensor)
Unit : PPM, mg/m3, %VOL
Display : Gas name, concentration unit, measured value, battery power
Alarm mode : Sound, light, vibration alarm, high and low alarm values can be set by yourself
Alarm type : Low alarm, high alarm, STEL, TWA, low battery optional calibration due and bump test due
Power supply mode : 3.6V dry battery (non-rechargeable
Explosion-proof grade : ExiaIICT4Ga
Protection class : IP68
Executive standards : GB 12358-2006, GB 3836.1-2010,GB 3836.4-2010, JJF1421-2013, JJF1363-2019, JJF1364-2012, JJG 365-2008, IEC 60079-0-2017, IEC 60079-11-2
Working temperature : -20℃~55℃
Working humidity: : 0-95%RH (non-condensing)
Working air pressure: : 86~106kpa
Dimensions: : 90*60*33mm (length*width*thickness)
Weight: : 125g (With Clip)
| 1. IP68 water- and dust-resistant case |
| 2. Low power consumption with 2 years standby time, no need battery charge and calibration |
| 3. With Single /multi unit docking station to perform daily bump test and calibration (Optional) |
| 4. With event and data logging function (optional) |
| 5. With self-test function, which can improve safety by automatic self-test |
| 6. Small size, light weight and with back clip for easily carry |
| 7. 95db@30cm buzzer alarm, 2 high-bright red LED light alarm and vibration alarm |
| 8. Real time value, TWA, STEL, MAX, MIN multiple data display |
| Gas Detected: Specified according to application. |
| Detection Principle: Diffusion |
| Measure range: Specified according to application. |
| Resolution: Specified according to application. |
| Accuracy: ≤±2-5%FS (depending on the specific sensor) |
| Response time(T90): 15-30s (depending on the specific sensor) |
| (Detection) Principle: Electrochemical principle |
| Unit: PPM, mg/m³, %VOL |
| Display: Gas name, concentration unit, measured value, battery power |
| Alarm mode: Sound, light, vibration alarm, high and low alarm values can be set by yourself |
| Alarm type: Low alarm, high alarm, STEL, TWA, low battery optional calibration due and bump test due |
| Power supply mode: 3.6V dry battery (non-rechargeable) |
| Explosion-proof grade: ExiaIICT4Ga |
| Protection class: IP68 |
| Executive standards: GB 12358-2006, GB 3836.1-2010, GB 3836.4-2010, JJF1421-2013, JJF1363-2019, JJF1364-2012, JJG 365-2008, IEC 60079-0-2017, IEC 60079-11-2 |
| Working temperature: -20℃~55℃ |
| Working humidity: 0-95%RH (non-condensing) |
| Working air pressure: 86~106kpa |
| Dimensions: 90×60×33mm (length×width×thickness) |
| Weight: 125g (With Clip) |
Product Description





Package
Company Information





Certifications


Cooperated Customers

FAQ


|
|
IECEX ATEX Certified Single Gas Detector with IP68 Protection Images |